\n","advanced":{"customState":[{"select":true,"label":"未处理","value":1},{"label":"审核通过","value":2},{"label":"审核驳回","value":3}],"message":1}},"href_7":{"type":"field","value":"_href","target":"_self"},"formId_9":"1097164222799245312","pageConfig_2":{"rolling":{"navigation":true,"scrollType":"horizontal","pagenation":true,"scrollTime":4,"autoScroll":true},"showJump":true,"pageType":"hidden","pcColumn":6,"marquee":{"navigation":true,"marqueeTime":4},"loopItem":".p_loopitem","pcRow":2,"moColumn":2},"showLabel_10":false,"validate_10":{"minLength":{"msg":"您输入的内容不能少于%len个字符","state":false,"value":5},"custom":{"msg":"","reg":"","state":false},"required":{"msg":"内容不能为空","value":true},"maxLength":{"msg":"您输入的内容不能多于%len个字符","state":false,"value":128}},"action_11":1,"showPlaceholder_10":true,"enterSubmit_10":true,"rule_9":[],"submit_9":{"obj2":{"type":"customPage","value":{"type":"page","params":[{"param":"_detailId","valueName":"单行文本","valueType":"value","paramName":"默认参数","type":"form","value":"e_input-10"}],"value":"bd5b650e-b336-4da1-b5fa-dc97019a7c1f"},"target":"_self"},"obj1":{"result":1,"request":[],"reload":1,"promptTime":2,"prompt":""},"logic":[],"type":2,"obj3":{}},"customParam_10":"","state_10":"normal","value_10":"","async_9":{"status":2,"target":"","relation":[]},"type_10":"text","cuname_10":"text","type_11":1,"page_2":{"size":6,"from":0,"totalCount":100},"reload_11":1,"ddItem_10":{},"sourceUuid_9":"1647484696445190144","placeholder_10":"请输入...","logic_11":[],"datasource_10":{},"notice_9":{"rules":[{"code":"submit","mail":"","phone":"","title":"搜索关键词","user":2}],"status":1},"prompt_11":"","href_3":{"type":"field","value":"_href","target":"_self"},"label_10":"单行文本","business_11":[],"logic_9":[]}">

淋雨试验机的摆管无法归位如何处理


2019-10-22


淋雨试验机主要由主机柜、副机柜、摆管、步进电机、水泵、控制系统等部件组成,其中摆管是决定淋雨试验机型号的关键因素。

通过淋雨试验机摆管与样品外壳的间距200mm这一标准,可以在R200R400R600R800R1000R1200R1400R1600中选择合适的摆管。

那么在淋雨试验机摆放的场地也要做好相应的防水处理,如地面和墙壁做防水涂层,地面做地漏和排水渠,房间内使用防水系列的电器。

淋雨试验机

有些客户在使用淋雨试验机一段时间后,发现在控制系统中点击摆管归零,但是摆管归零后还是与规定刻度有一定的误差,这种情况如何进行校准呢?

岳信售后服务部的王工在这里为您解答:

1. 原因:淋雨试验机在使用一段时间后,因使用频率过多或者在使用过程中被碰撞,未及时进行调整校正,造成摆管的位置有偏差,无法达到归零位置。

2. 解决方案:

l 检查主机柜和副机柜的位置是否在同一水平位置,未在同一水平位置的,请及时调整。

l 检查主机柜和副机柜的间距是否造成摆管变形,发现变形及时调整间距。

淋雨试验机

l 检查主机柜和副机柜的脚轮是否固定,为固定请及时将4个脚轮锁死。

l 检查摆管与归零角度的误差值,将主机柜打开,手动调节步进电机感应电磁片,对角度进行微调,调整到摆管垂直于样品转台,与归零位置重叠。

l 反复试验摆管上下摆动后,是否能回位归零,未归零继续按照上一个步骤进行调试,直至摆管归零。

以上就是解决淋雨试验机摆管不归零的方案,希望对大家有所帮助,如遇其它原因可随时联系我司在线售后服务部为您服务。