\n","advanced":{"customState":[{"select":true,"label":"未处理","value":1},{"label":"审核通过","value":2},{"label":"审核驳回","value":3}],"message":1}},"href_7":{"type":"field","value":"_href","target":"_self"},"formId_9":"1097164222799245312","pageConfig_2":{"rolling":{"navigation":true,"scrollType":"horizontal","pagenation":true,"scrollTime":4,"autoScroll":true},"showJump":true,"pageType":"hidden","pcColumn":6,"marquee":{"navigation":true,"marqueeTime":4},"loopItem":".p_loopitem","pcRow":2,"moColumn":2},"showLabel_10":false,"validate_10":{"minLength":{"msg":"您输入的内容不能少于%len个字符","state":false,"value":5},"custom":{"msg":"","reg":"","state":false},"required":{"msg":"内容不能为空","value":true},"maxLength":{"msg":"您输入的内容不能多于%len个字符","state":false,"value":128}},"action_11":1,"showPlaceholder_10":true,"enterSubmit_10":true,"rule_9":[],"submit_9":{"obj2":{"type":"customPage","value":{"type":"page","params":[{"param":"_detailId","valueName":"单行文本","valueType":"value","paramName":"默认参数","type":"form","value":"e_input-10"}],"value":"bd5b650e-b336-4da1-b5fa-dc97019a7c1f"},"target":"_self"},"obj1":{"result":1,"request":[],"reload":1,"promptTime":2,"prompt":""},"logic":[],"type":2,"obj3":{}},"customParam_10":"","state_10":"normal","value_10":"","async_9":{"status":2,"target":"","relation":[]},"type_10":"text","cuname_10":"text","type_11":1,"page_2":{"size":6,"from":0,"totalCount":100},"reload_11":1,"ddItem_10":{},"sourceUuid_9":"1647484696445190144","placeholder_10":"请输入...","logic_11":[],"datasource_10":{},"notice_9":{"rules":[{"code":"submit","mail":"","phone":"","title":"搜索关键词","user":2}],"status":1},"prompt_11":"","href_3":{"type":"field","value":"_href","target":"_self"},"label_10":"单行文本","business_11":[],"logic_9":[]}">

滴雨试验箱无法启动的七种解决办法


2019-10-19


滴雨试验箱是通过模拟自然界雨滴环境,对产品外壳表面进行防滴水检验,通常适用于电子元件、户外灯具、汽车配件、数码产品等。

在长时间使用滴雨试验箱进行检验的同时,总是会遇到一些小问题,通过岳信售后工程师提供的数据分析,滴雨试验箱不启动的原因比较常见,这里小编给大家罗列出七种解决办法,供大家参考:

滴雨试验箱

1. 连接滴雨试验箱的水源、电源、气源,开机后发现不启动,检查水源是否打开,电源开关是否打开。

2. 通常情况下,滴雨试验箱在出厂前会将流量计调节至最小值,所以在测试前,请将流量计调节打开。

3. 检查滴雨试验箱的过滤器,滤芯变黑会造成水路的堵塞,无法启动。请在3个月左右的时间内更换新的滤芯。

滴雨试验箱

4. 滴雨试验箱的滴雨板旁边,安装有红外线感应器,为了防止滴水板触碰到人体或物体,检查是否有异物遮挡住感应器。

5. 滴雨试验箱滴雨板内有锈迹、污垢、杂质,造成无水滴淋,请打开控制系统上的排气开关,利用空气压,将滴水板内的污垢排出,同时更换变形的针头。

6. 滴雨试验箱的控制系统与滴水板的升降系统,是通过防水连接线连接的,发现不启动,请及时检查连接线是否按照规定连接。

7. 滴雨试验箱无法启动,因滴水板是通过升降杆旋转上升或下降的,请检查升降杆部位是否有异物卡住,及时进行清理。

通过上述七种解决滴雨试验箱不启动的方案,如您还有其它的疑问,可以随时联系我司售后服务中心为您解答。