\n","advanced":{"customState":[{"select":true,"label":"未处理","value":1},{"label":"审核通过","value":2},{"label":"审核驳回","value":3}],"message":1}},"href_7":{"type":"field","value":"_href","target":"_self"},"formId_9":"1097164222799245312","pageConfig_2":{"rolling":{"navigation":true,"scrollType":"horizontal","pagenation":true,"scrollTime":4,"autoScroll":true},"showJump":true,"pageType":"hidden","pcColumn":6,"marquee":{"navigation":true,"marqueeTime":4},"loopItem":".p_loopitem","pcRow":2,"moColumn":2},"showLabel_10":false,"validate_10":{"minLength":{"msg":"您输入的内容不能少于%len个字符","state":false,"value":5},"custom":{"msg":"","reg":"","state":false},"required":{"msg":"内容不能为空","value":true},"maxLength":{"msg":"您输入的内容不能多于%len个字符","state":false,"value":128}},"action_11":1,"showPlaceholder_10":true,"enterSubmit_10":true,"rule_9":[],"submit_9":{"obj2":{"type":"customPage","value":{"type":"page","params":[{"param":"_detailId","valueName":"单行文本","valueType":"value","paramName":"默认参数","type":"form","value":"e_input-10"}],"value":"bd5b650e-b336-4da1-b5fa-dc97019a7c1f"},"target":"_self"},"obj1":{"result":1,"request":[],"reload":1,"promptTime":2,"prompt":""},"logic":[],"type":2,"obj3":{}},"customParam_10":"","state_10":"normal","value_10":"","async_9":{"status":2,"target":"","relation":[]},"type_10":"text","cuname_10":"text","type_11":1,"page_2":{"size":6,"from":0,"totalCount":100},"reload_11":1,"ddItem_10":{},"sourceUuid_9":"1647484696445190144","placeholder_10":"请输入...","logic_11":[],"datasource_10":{},"notice_9":{"rules":[{"code":"submit","mail":"","phone":"","title":"搜索关键词","user":2}],"status":1},"prompt_11":"","href_3":{"type":"field","value":"_href","target":"_self"},"label_10":"单行文本","business_11":[],"logic_9":[]}">

臭氧老化试验机的故障及处理方法


2024-07-24


臭氧老化试验机,又可以叫臭氧老化实验箱或臭氧试验设备等,一种用于测试橡胶类制品,如硫化橡胶、热塑性橡胶、电缆绝缘护套等在臭氧环境下的老化性能的设备。

有的用户可能在使用臭氧老化试验机的过程中,遇到了一些突然故障,本文将介绍有关于该设备的一些的判断及解决方法:

臭氧老化试验机

一、升温无法控制

故障现象:设备无法按设定温度升温或温度波动过大。

判断方法:

1.检查温控器:观察温控器面板上的指示灯是否正常,如有异常(如一直点亮不熄灭),可能需要更换新的温控器。

2.检查电磁开关:确认电磁开关的接点是否卡住或不良,以及无接点开关是否有短路或断路情况。

3.检查电热器:检查电热器是否断线或损坏,导致加热功能失效。

4.检查电压:确保电源电压稳定,电压不足也会影响升温效果。

三、无报警声

故障现象:设备在出现故障时未发出报警声。

判断方法:

1.检查报警器是否损坏或故障,无法发出声音报警。

四、设备发出的噪音大

故障现象:设备运行时发出异常噪音。

判断方法:

1.检查地基:确认设备地基是否平整,安装是否稳固。

2.检查配管:检查设备配管是否松动或振动,导致噪音产生。

3.检查风轮:确认风轮是否脱落或损坏,影响设备正常运行。

以上关于臭氧老化试验机的故障及处理方法的介绍。