\n","advanced":{"customState":[{"select":true,"label":"未处理","value":1},{"label":"审核通过","value":2},{"label":"审核驳回","value":3}],"message":1}},"href_7":{"type":"field","value":"_href","target":"_self"},"formId_9":"1097164222799245312","pageConfig_2":{"rolling":{"navigation":true,"scrollType":"horizontal","pagenation":true,"scrollTime":4,"autoScroll":true},"showJump":true,"pageType":"hidden","pcColumn":6,"marquee":{"navigation":true,"marqueeTime":4},"loopItem":".p_loopitem","pcRow":2,"moColumn":2},"showLabel_10":false,"validate_10":{"minLength":{"msg":"您输入的内容不能少于%len个字符","state":false,"value":5},"custom":{"msg":"","reg":"","state":false},"required":{"msg":"内容不能为空","value":true},"maxLength":{"msg":"您输入的内容不能多于%len个字符","state":false,"value":128}},"action_11":1,"showPlaceholder_10":true,"enterSubmit_10":true,"rule_9":[],"submit_9":{"obj2":{"type":"customPage","value":{"type":"page","params":[{"param":"_detailId","valueName":"单行文本","valueType":"value","paramName":"默认参数","type":"form","value":"e_input-10"}],"value":"bd5b650e-b336-4da1-b5fa-dc97019a7c1f"},"target":"_self"},"obj1":{"result":1,"request":[],"reload":1,"promptTime":2,"prompt":""},"logic":[],"type":2,"obj3":{}},"customParam_10":"","state_10":"normal","value_10":"","async_9":{"status":2,"target":"","relation":[]},"type_10":"text","cuname_10":"text","type_11":1,"page_2":{"size":6,"from":0,"totalCount":100},"reload_11":1,"ddItem_10":{},"sourceUuid_9":"1647484696445190144","placeholder_10":"请输入...","logic_11":[],"datasource_10":{},"notice_9":{"rules":[{"code":"submit","mail":"","phone":"","title":"搜索关键词","user":2}],"status":1},"prompt_11":"","href_3":{"type":"field","value":"_href","target":"_self"},"label_10":"单行文本","business_11":[],"logic_9":[]}">

沙尘试验机滑石粉怎么样更换


2024-04-19


沙尘试验机用于模拟沙尘环境,以检验产品在此类环境下的密封性和耐腐蚀程度。滑石粉作为试验中使用的介质,需要定期更换以保证试验的准确性和设备的正常运行。以下是更换沙尘试验机中滑石粉的一般步骤:

沙尘试验机

1.准备工作:在更换滑石粉之前,需要先将新的滑石粉干燥一遍,以便于更换。

2.关闭设备:确保沙尘试验机已经关闭并断电,以保证安全进行更换工作。

3.打开箱门:打开沙尘试验机的箱门,使用毛刷或其他工具将内箱上的滑石粉清理出来。

4.清理粉尘:用刷子细心清理尾门、密封垫片、视窗、不锈钢筛网、照明灯具等部件上的滑石粉。

5.拆卸和清理:打开沙尘试验箱的侧面下边的连板,敲打设备底部,使滑石粉坠落到底端的收集容器中。

6.更换滑石粉:将旧的滑石粉完全清干净后,通过设备的漏斗或添加口,将新的滑石粉倒入箱内。

7.检查和测试:更换完毕后,检查设备内部是否还有残留的旧滑石粉,并进行必要的清理。之后,进行一次测试运行,确保滑石粉流动正常,设备工作稳定。

8.注意事项:在更换过程中,注意不要让滑石粉外溢,避免对设备周围环境造成污染。同时,确保操作人员的健康安全,必要时佩戴口罩和手套。

9.定期更换:根据设备制造商的建议,定期更换滑石粉,一般建议每使用20次左右更换一次,以保证试验效果。

通过遵循上述步骤,可以有效地更换沙尘试验机中的滑石粉,确保试验的准确性和设备的正常运行。