\n","advanced":{"customState":[{"select":true,"label":"未处理","value":1},{"label":"审核通过","value":2},{"label":"审核驳回","value":3}],"message":1}},"href_7":{"type":"field","value":"_href","target":"_self"},"formId_9":"1097164222799245312","pageConfig_2":{"rolling":{"navigation":true,"scrollType":"horizontal","pagenation":true,"scrollTime":4,"autoScroll":true},"showJump":true,"pageType":"hidden","pcColumn":6,"marquee":{"navigation":true,"marqueeTime":4},"loopItem":".p_loopitem","pcRow":2,"moColumn":2},"showLabel_10":false,"validate_10":{"minLength":{"msg":"您输入的内容不能少于%len个字符","state":false,"value":5},"custom":{"msg":"","reg":"","state":false},"required":{"msg":"内容不能为空","value":true},"maxLength":{"msg":"您输入的内容不能多于%len个字符","state":false,"value":128}},"action_11":1,"showPlaceholder_10":true,"enterSubmit_10":true,"rule_9":[],"submit_9":{"obj2":{"type":"customPage","value":{"type":"page","params":[{"param":"_detailId","valueName":"单行文本","valueType":"value","paramName":"默认参数","type":"form","value":"e_input-10"}],"value":"bd5b650e-b336-4da1-b5fa-dc97019a7c1f"},"target":"_self"},"obj1":{"result":1,"request":[],"reload":1,"promptTime":2,"prompt":""},"logic":[],"type":2,"obj3":{}},"customParam_10":"","state_10":"normal","value_10":"","async_9":{"status":2,"target":"","relation":[]},"type_10":"text","cuname_10":"text","type_11":1,"page_2":{"size":6,"from":0,"totalCount":100},"reload_11":1,"ddItem_10":{},"sourceUuid_9":"1647484696445190144","placeholder_10":"请输入...","logic_11":[],"datasource_10":{},"notice_9":{"rules":[{"code":"submit","mail":"","phone":"","title":"搜索关键词","user":2}],"status":1},"prompt_11":"","href_3":{"type":"field","value":"_href","target":"_self"},"label_10":"单行文本","business_11":[],"logic_9":[]}">

气密性测试仪常见故障以及处理方法


2023-11-04


气密性测试仪通常由压力传感器、气源、控制单元等组成。根据测试原理和测试对象的不同,气密性测试仪的种类和用途也有所不同。,下面详细介绍该测试仪的常见故障以及处理方法包括:

气密性测试仪

1、灵敏度不够:可能是由传感器故障、压力源问题或配置设置错误引起的。解决方法是校准或更换传感器,检查供气系统或替换失效的零件,重新进行设置并进行校准。

2、测试结果不准确:可能是操作不当、零件松动、密封不良或排气不畅引起的。解决方法是仔细检查测试过程中的操作环节,如安装密封件是否正确、紧固螺栓是否牢固等,并确保测试环境的温度、湿度等参数符合要求。

3、仪器无法正常启动:可能是电路故障、电源问题或控制软件错误等造成的。解决方法是检查电路是否有损坏或出现故障,排除电路问题,检查电力供应是否正常,以确保仪器的电源正常工作。

4、机械阻力大:可能是传动系统、导轨或滑动部件中积聚了杂质或润滑不足导致的。解决方法是定期清理和润滑传动系统,并检查导轨和滑动部件的磨损情况。

5、操作手柄松动:可能是螺丝未紧固好或手柄损坏而引起的。解决方法是检查操作手柄附着的螺丝是否有松动,紧固螺丝或更换手柄。

6、操作不灵活:可能是传动链条、摆轮系统或其他机械齿轮组件出现了故障。解决方法是润滑链条和齿轮,并进行必要的维修或更换预防变形和生锈。

以上关于气密性测试仪的常见问题信息仅供参考,如遇到无法解决的问题,建议咨询专业人士获取帮助。